Preview build. Contact details, credentials and prices are placeholders until the owner supplies them. This page is noindex.

Toronto · Peel · Halton · Hamilton · Niagara

ICF foundations and full-height walls.

Insulated concrete form walls, formed, reinforced and poured by our own crew. Insulated on both faces the day they are poured, built year-round, with any ICF system your local supplier stocks.

22

municipalities served, Toronto to Fort Erie

1 business day

to call you back on every request

Free

quote, with a firm price once we have seen the drawings or the site

What we build

Foundations and basements
Footings, ICF walls poured in one lift, membrane and weeping tile, ready for framing. A basement that is insulated the day it is poured, with no furring, batts or vapour barrier to add later.
Full-height walls
Whole houses and storeys above grade in ICF, with the engineer sizing lintels and bearing for the openings. Quiet, solid and airtight in a way framed walls are not.
Additions and garages
A new foundation and walls tied into an existing house, or a garage that wants to be warm. Same crew, same system, sized to the drawings.

How an ICF wall is built

Section through an ICF foundation wall Cross-section. A concrete footing sits below the frost zone. On it stands a wall made of two layers of EPS foam form with a reinforced concrete core between them. The outside face carries a waterproofing membrane down to a weeping tile beside the footing; the inside face meets a basement slab. Grade is near the top of the wall. Grade Frost zone to 1.2 m Undisturbed soil 4 Basement slab Floor framing above 1 2 3 ICF foundation wall
  1. EPS foam forms on both faces stay in place as the wall's insulation.
  2. A reinforced concrete core, poured in one lift, carries the load.
  3. A waterproofing membrane on the outside face runs down to the weeping tile at the footing.
  4. The footing bears in undisturbed soil below the frost zone.
Not to scale. 1.2 m is the minimum footing depth on Halton municipalities' own drawings and the design frost depth in geotechnical reports filed with the Town of Oakville.
  • Insulated on both faces from day one. The foam form is the insulation, continuous around the wall with no studs to bridge it. The R-value question is answered in the guide, with the difference between nominal and effective spelled out.
  • Reinforced concrete core. Steel placed in the form, concrete poured in one continuous lift, inspected before the pour. The engineer sets the core thickness and the reinforcing from the loads.
  • Poured year-round. The form keeps the concrete warm while it cures, so winter pours go ahead with the usual cold-weather measures instead of a wait for spring.
  • Waterproofed like any foundation. Membrane and weeping tile outside, to the code and the manufacturer's detail. The foam is insulation, not waterproofing, and we say so.

How it works

  1. Send the drawings

    Architectural drawings with wall heights and the perimeter are enough to quote. For an addition or a retrofit, a sketch and photos start the conversation and we take measurements on site.

  2. Engineering and permit package

    The engineer sizes the core, the reinforcing and the lintels to the loads and the soil, and the drawings, the ICF system's documentation and the engineer's letter go in with the permit application. We prepare the package with you.

  3. Footings, forms, steel, pour

    Our crew sets the footings, stacks and braces the forms, places the reinforcing, and pours the walls in one continuous lift with the concrete inspected and the forms staying in place as the insulation.

  4. Waterproof, backfill, hand over

    The outside face gets its membrane and weeping tile, the pre-backfill inspection is booked, and the framers take over on a wall that is already insulated on both faces.

What it costs, illustratively

Ranges from our current price table, per square foot of wall installed. Each site carries its own conditions, so treat these as examples and the written quote as the price.

WallTypical coreIllustrative range
Foundation and basement walls 6 in or 8 in concrete core $38 to $55 per sq ft of wall installed
Full-height above-grade walls 6 in core typical above grade; 8 in where the wall below is 8 in $42 to $55 per sq ft of wall installed
Additions and garage walls 6 in core typical; 8 in where the engineer or the wall above requires it $42 to $58 per sq ft of wall installed

Last reviewed 2026-09-25. Typically outside the per-sq-ft wall figure: excavation and shoring; footings (formwork, rebar, concrete); dampproofing or waterproofing membrane and protection board; weeping tile, drainage layer and stone (required by OBC 9.13 and 9.14 and inspected before backfill); backfill and grading; window and door bucks and lintels beyond standard openings; structural engineering and the Toronto Assumption of Responsibility form where an engineer seals the drawings; permit fees; concrete pump truck; winter heating, hoarding and cold-weather admixtures (ICFpro cites a 20-30% concrete premium in shoulder seasons); brick ledge or taper-top forms; interior finishes and thermal-barrier drywall. Full breakdown against poured concrete, what other Ontario builders publish, and a calculator: ICF vs poured concrete foundations in Ontario.

Where we work

We work across Toronto, Peel, Halton, Hamilton, Guelph and the Niagara corridor down to Fort Erie.

Questions people ask

What is an ICF wall?

Insulated concrete forms are interlocking blocks of expanded polystyrene foam with plastic webs between them. They stack like oversized bricks, get reinforcing steel placed inside, and are filled with concrete. Unlike plywood forms, the foam stays in place after the pour, so the finished wall is reinforced concrete with continuous insulation on both faces.

Which ICF brand do you use?

Whichever system the local supplier has in stock for the job. The Building Code asks that ICF units conform to CAN/ULC-S717.1, and every system we install meets that standard; some also carry a CCMC evaluation report. We name the system on your quote and its documentation goes in the permit package. Not being tied to one brand keeps lead times short and the price honest.

Can you pour in winter?

Yes. The foam form insulates the concrete while it cures, which is one of the practical reasons ICF is chosen for winter builds. Cold-weather concreting still has rules: the concrete arrives warm, the top of the wall is covered, and the schedule allows for the cure. We build year-round and price the winter measures into the quote.

Do I still need waterproofing below grade?

Yes. The foam is not a waterproofing layer. Below grade the outside face gets a membrane or damp-proofing to the code and the manufacturer's detail, with a weeping tile at the footing, exactly as a poured wall would. The difference is that the insulation is already there when the membrane goes on.

Is ICF more expensive than a poured foundation?

The wall itself usually costs more than a bare poured wall and less than a poured wall once you add the insulation, furring and vapour barrier a finished basement needs. Our price table on this site is illustrative and per square foot of wall, and the written quote after a site review is the number you pay.

Do you build full-height ICF houses, not just basements?

Yes. Foundations are the most common ICF job, but our crew builds full-height ICF walls for whole houses, additions and garages as well. Above grade, the same wall gives you the insulation, the sound performance and the solid feel; the engineer sizes lintels and bearing for the openings.

Ready for a firm price?

Send the drawings and we call you back within one business day. Free, and no obligation.